Single Fiber Fusion Splicer

4.3 inch screen AT4108H
Contact Us

Description

Features

Handheld, Small, Light ;
8s splicing time, 26s tube heating time;
5800mAh and pluggable Li-battery. ;
Typical 200 cycles;
USB port for software updating anddata records exporting;
ARC calibrated by temperature andair pressure automatically;

Applications

Maintenance in Telecom
Maintenance CATV
Fiber Optic Lab Testing
Other Fiber Optic Measurements

Specification

Applicable fiber

SM (ITU-T G.652&G.657), MM (ITU-T  G.652&G.657)

DS (ITU-T G.652&G.657), NZDS (ITU-T G.652&G.657).

Fiber count

Single

Cladding Length

Cladding diameter: 80-150μm, 

Coating diameter: 160-900μm

Typical splice loss

SM: 0.02dB  

MM: 0.01dB 

DS: 0.04dB 

NZDS: 0.04dB

G.657: 0.02dB (ITU-T Standard)

Return loss>60dB

Fiber cleaved length

10-16mm (coating diameter< 250μm),

16mm (coating diameter: 250-1000μm)

Splicing program40 groups
Operate modeManual, Automatic

Auto-heating

Available

Typical splicing time8 seconds
Tube heating time

26 seconds for 60mm and 40mm shrinkable sleeves

Fiber view magnification250X (X or Y view), 125X (X and Y view)
Viewing method and display2 CMOS cameras, 4.3 inch color LCD monitor
Storage of splice result

4000 results

Tension test

1.8-2.2 N
InterfaceGUl menu interface, easier operation
Battery capacity

5200mAh Battery Capacity, typical times (splice and tube heat)

Power supplyAdaptor, input: AC100-240V(50/60HZ)

Electrode life

More  than  4000  ARC  discharges,  can  be  replaced conveniently

Terminals

USB 2.0 port, for uploading splice results and upgrading software
Operating condition

Altitude: 0-5000m, 

Humidity: 0-95%,

Temperature:-10℃~+50℃;

Wind speed: max 15m/s

Dimension149mm(L) × 120mm(W) × 127mm(H)
Weight

1.9kg including battery